Allowing water to breathe & restructure
The biomimetic principles of clean, crisp, mountain-fresh drinking water is now available under your kitchen sink
Our unique 7-Part process

"We do for a moment, invite water to breathe
The longectivity of any molecular restructuring of water is un known so we surpass all myths with allowing the water to breathe in that minute moment of restructuring.
With advanced and considered pre treatments that ensure the optimal wholesome nature of drinking water.
Hold up to the light and say cheers to optimal hydration"​

Foundations
Grounded in first-principles fluid mechanics, chemical reaction kinetics, and certified membrane physics.
​
Many commercial restructuring gadgets claim to break water into "smaller clusters" or "hexagonal structures." In reality, liquid water is a dynamic hydrogen-bonded network that breaks and reforms billions of times per second. Without a continuous physical boundary (like a hydrophilic surface for EZ water), bulk water cannot maintain an altered structural state after passing through a passive device.
​
When looking across the market, commercial "restructuring," "vortexing," or "energised water" device sellers routinely make a specific set of claims.
Our 7-stage architecture delivers those target outcomes through verifiable physical mechanics, chemical kinetics, and fluid dynamics instead of unproven structural theories.

The Princiles of filtration
Mass Market "Restructuring" Device Approach
V
Our 7-Stage Process Approach
​
Pathogen & Contaminant Removal
Mass market
Assumed through "self-cleansing" field properties (unproven) or substandard unconsidered pre treatement as an optional extra
Our 7-part
Absolute capture via 3-part pre-treatment and 0.01-micron physical barriers.
Hardness & Scale Reduction
Mass market
Magnetic/catalytic crystal shape alteration presumptions
Our 7-part
Stage 4 (true chemical ion swapping).
Palatability & Freshness
Mass market
Passive vortex geometric spin.
Our 7-part
Stages 2,3&6
Hydration Performance
Mass market
Claims of permanent molecular restructuring.
Our 7-part
Organoleptic optimisation driving higher actual volumetric compliance*.
Using Benouli principles of flow dynamics and EBCT filter media.
*Presumed and open for challenge
The Limits of our knowledge
The persistence of changes associated with fluid dynamics, interfacial phenomena, and gas–liquid saturation depends on the underlying physical processes, including Henry’s law, fluid motion and bulk thermodynamics.
The sections below explain why these effects are transient and how a fresh POU system can make use of them at the point of drinking.
How Long Do These Effects Last?
1. Principled Oxygenation: Dissolved Gas Stability
-
Oxygenation under pressure. A properly designed air injector introduces microbubbles downstream of the physical media. This can bring dissolved oxygen (DO) toward atmospheric equilibrium or cause slight supersaturation, depending on the pressure in the line. Henry’s law and the gas’s partial pressure govern this equilibrium.
-
Degassing after pouring. Once the water leaves the pressurised system and enters an open container at ambient pressure, excess dissolved oxygen begins to escape.
-
Temperature effects. As the poured water warms to room temperature, its capacity to hold dissolved gas decreases, allowing oxygen to come out of solution.
-
Expected persistence. Microbubbles may remain visibly suspended for a few minutes. Dissolved oxygen then gradually returns towards room-temperature equilibrium over minutes to a few hours.
Restructured Water: Hydrodynamic and Molecular Effects
-
Interfacial effects versus bulk behaviour. Ordering phenomena, such as exclusion-zone layers and transient changes in the hydrogen-bond network, occur at fluid interfaces or under active shear. These should be distinguished from bulk liquid behaviour.
-
Rapid molecular relaxation. Thermal fluctuations continually rearrange hydrogen bonds between water molecules, with relaxation occurring on picosecond timescales.
-
Limits during storage. Changes induced by high-velocity shear, magnetic fields or contact with minerals are described here as metastable rather than permanent. Examples include altered surface tension, transient orientation of hydration shells around dissolved cations, and small-scale vortical motion. Once the water is stored without flow in a glass or bottle, thermal molecular motion drives it back towards equilibrium.
Because structured ordering and micro-aeration degrade over time once exposed to room temperature and static air, water cannot be "permanently structured" or statically bottled without losing these dynamic properties. Treating municipal tap water through sequential physical filtration and terminal Venturi aeration at the exact moment of dispense guarantees that you drink the water at its absolute peak of purity, gas saturation, and sensory freshness.

Investment and Installation
Full system fully installed
£1,100
Annual service
£199
Existing 4-part Upgrade
£399+£150 (current system service)
Annual service
£199
​
Scope of works
Cabinet space
Pipe access
Pressure and flow parameters
Image shown
proof of concept

Pre treatment assurances
We fully protect our process filtration system with a patented Submicron Depth Filter Cartridge at a critical stage
Engineered with advanced electro-adsorptive media technology, this cartridge delivers the rigorous purification efficiency of ultra-membrane filtration but with exceptionally high flow rates and zero wasted water.
By using a natural electropositive charge field instead of a tight mechanical squeeze, it pulls contaminants out of the water like a magnet while maintaining an ultra-low pressure drop.
Key Benefits & Technology
Electropositive Adsorption:
Attracts and traps submicron pathogens, heavy metals, and cellular debris.
PAC & Silver Matrix:
Powdered Activated Carbon (PAC) eliminates tastes and odours, while the silver lining prevents bacterial growth inside the housing.
High Loading Capacity:
Lasts up to 25 times longer than standard mechanical media.
Versatile Performance:
Functions perfectly across a wide 4–9 pH window in fresh, brackish, or salt water.
Lab-Tested Performance Metrics
Viruses (Polio, Rotavirus, Norovirus): >99.99% removal
Bacteria (E. coli, Legionella, Pseudomonas): >99.9999% removal
Cysts (Giardia, Cryptosporidium): >99.95% removal
Heavy Metals (Lead, Arsenic V, Cadmium): >95% reduction
Other Metals (Chromium, Iron, Selenium, Mercury): 60% – 85% reduction
Chemicals & Toxins (Chlorine, VOCs, PCBs, BPA): High reduction
Modern Pollutants (Microplastics, Pharmaceuticals, Hormones): High reduction
(Note: Particle retention capacity is equivalent to a 0.02-micron size for virus removal. Tested at 6.5 pH.)
Certifications & Compliance
NSF/ANSI Standards 42 & 61 Certified Media
IAPMO UPC Certified (Drinking Water System Components)
USP Class VI and Endotoxin Tested


